Nitrogen Enhanced Purging System 1000 Dual Voltage

The Nitrogen purging system 1000 dual voltage is a fully self-contained, portable nitrogen purging system that maximises dry gas purging. It can be operated easily by connecting the equipment to the purge connecting the device. The purging system also has a moisture adsorbing agent, molecular sieves, and a self-contained pump to enable users to operate in the field or workshop environment.

Optimised Gas and Purging Procedure

Designed with user-friendly features, this nitrogen blanketing system can be programmed to view process control values and display dewpoint measurements in Degrees Celsius and Fahrenheit with pressure in Kpa or psi.

Featuring a selection of four in-built testing capabilities, the nitrogen gas purifier allows verification of sealing standards of the equipment to be purged. Pressure testing can be done in pressures from 10.3 Kpa (1.5 psi) to 34.4 Kpa (5.0 psi). The pressure leak rate display solution is 0.01 psi.

The dewpoint monitor provides users with the dryness of the gas before the commencement of the purging operation. Equipped with a dewpoint stat, users can determine the moisture content within the equipment and implement an optimised gas and purging procedure for product control.

Dewpoint Monitor for Precise Purging

When the dewpoint sensor option is removed, the nitrogen gas purging system will monitor the progress of the dewpoint dryings, switching off and isolating the dry gas automatically when the selected dewpoint is achieved. A data logger can also monitor dewpoint degradation time, allowing users to calculate the water vapour transmission rate and determine the water removal rate required during the initial purging phase.

The system is highly versatile and can be operated from global country voltages and frequencies ranging between 100 to 230 VAC at 50-60 HZ. A 24VDC version is also available. The nitrogen purge unit is suitable for applications that involve surveillance instruments, image intensifiers, thermal imaging, underwater equipment, optical instruments, and electrical housings.

  • Fully self-contained and portable design
  • Maximises dry gas purging efficiency
  • User-friendly programming and control
  • Dewpoint measurements in Celsius and Fahrenheit
  • In-built testing for equipment sealing verification
  • Pressure testing in the range of 10.3 Kpa to 34.4 Kpa
  • Dewpoint monitor for gas dryness assessment
  • Optimise gas and purging procedures with dewpoint stat
  • Automatic gas isolation at selected dewpoint
  • Data logger for tracking dewpoint degradation
  • Versatile operation with global voltage compatibility
  • Suitable for surveillance, thermal imaging, and more
Display Range Pressure 0 to 34.4 Kpa (0-5.0 psi)
Display Range Dewpoint (Selectable)
+20ºC to –80ºC dewpoint
+68ºF to –94ºF dewpoint
Resolution 0.1ºC dewpoint
Accuracy +/- 2ºC dewpoint
Data Output Pressure 0 – 5 Volts
Data Output Dewpoint 0 – 5 Volts
Power 1 100-230 volt 50-60hz
Power Consumption 3 amps
Power 2 24 VDC
Power Consumption 3 amps
Dimensions 490W x 425D x 190H (closed)
Weight 15 kilograms
Ingress Protection IP54 (Closed Case)
Operating Temp -10ºC to +50ºC
Storage Temp -50ºC to + 65ºC
Flowrate (typical) 20 litres per minute