Nitrogen Enhanced Purging System 1000 Advantage

Nitrogen Enhanced Purging System 1000 Advantage

The Nitrogen Purging System 1000 Advantage (NEPS1000) is designed to offer efficient and effective use of dry nitrogen, which purges electronic, high voltage, optical, and equipment that require drying of gas while inhibiting oxygen. The NEPS1000 Advantage is a user-friendly purging system that connects the dry gas source to the inlet connection and the equipment port. It also allows easy configuration of settings to allow users to view the process in control values and display dewpoint measurements in Fahrenheit or Degree Celsius with pressure in Kpa or psi. Furthermore, its high visible liquid displays offer constant updated information and readouts during operation.

Featuring a selection of four in-built testing capabilities, the NEPS1000 Advantage allows verification of sealing standards of the equipment to be purged. The pressure leak rate display solution is 0.01 psi. Pressure testing can be done in pressures from 10.3 Kpa (1.5 psi) to 34.4 Kpa (5.0 psi). The NEPS1000 Advantage also allows users to check the dryness of the gas before the purging operation through the dewpoint monitor. This is useful for stating the quality control requirement needed for purging and instrument or enclosure.

The Dewpointstat feature of the NEPS1000 Advantage allows users to determine the volume of moisture required to be contained within a piece of equipment and implement an optimised gas and purging procedure for production control. The remote dewpoint sensor option allows users to keep track of the progress of dewpoint dryness within the system once purging begins. When the selected dewpoint is met, the system then switches off and isolates the dry gas. The system is highly versatile and can be operated from global country voltages and frequencies ranging between 100 to 230 VAC at 50-60 HZ. The NEPS1000 Advantage is ideal for applications that involve laser systems, SF6 switchgear, storage containers, optical instruments, underwater, and surveillance equipment.

  • Easy-to-use Single Connection Purging
  • Dewpoint and Pressure Readout
  • Dewpoint Stat Gas Control
  • Dewpoint display from 20ºC to -80ºC
  • Remote Dewpoint Sensing Option
  • Portable and robust
  • User-programmable
  • Automatic Purging Operation
  • Maintainable online
  • NATO Approved
  • Useable Gases: Air, nitrogen, SF6, helium argon
  • Selectable Pressure Range: 10.3kpa/17.2kpa/34.4kpa
  • Display Range Pressure : 0 to 34.4kpa
  • Display Range Dewpoint: 20 to -80 degrees/+68F to -94F dewpoint/0.1 degrees
  • Resolution: 0.1 degrees dewpoint
  • Accuracy: +/- 2 degrees dewpoint
  • Data Output Pressure: 0-5 volts
  • Data Output Dewpoint: 0-5 volts
  • Power: 100-230 volt 50Hz – 60Hz
  • Power Consumption: 3 Amps
  • Dimensions (W x D x H): 490 x 425 x 190 (closed)
  • Weight: 12kg
  • Ingree Protection: 1P54 (closed case)
  • Operating Temperature: -10ºC to 50ºC
  • Storage Temperature: -50ºC to 65ºC
  • Proof Pressure Input: 137kpa (20 psi)
  • Flow Rate: 20 litres/min
  • Optional Extras: See NEPS accesories

Nitrogen Enhanced Purging System 1000 Advantage Product Brochure: Download

Enquire About Product