Single-Use Temperature Data Logger

The single-use temperature data logger is a cost-effective solution for measuring and recording real-time temperature readings over a range of -30°C to 60°C (-13°F to 140°F). The one-time use temperature logger also has an 8,000 log memory and can be stored for up to two years in standard hibernation mode. It offers continuous operation for six months, ensuring reliable long-term monitoring.

The device has a red “ALERT” indicator that immediately notifies users if any readings are outside the specified limits during configuration. A green “OK” indicator indicates normal operation.  Configuration is easily done by connecting the data logger directly to a computer’s USB port, allowing various recording and alert conditions. The recorded data can be downloaded in a detailed PDF report using the Analyser software.

  • Cost-effective solution for real-time temperature readings (-30°C to 60°C / -13°F to 140°F)
  • 8,000 log memory and up to two years of storage in standard hibernation mode
  • Continuous operation for six months, ensuring reliable long-term monitoring
  • Red “ALERT” indicator for immediate notification of readings outside specified limits
  • Green “OK” indicator for normal operation status
  • Easy configuration via USB connection to a computer
  • Free LogTag Analyser software for detailed PDF report downloads
  • Sensor Measurement Range: -25°C to 60°C (-13°F to 140°F)
  • Operating Temperature Range: -25°C to 60°C (-13°F to 140°F)
  • Storage Temperature Range: 0°C to 40°C (32°F to 104°F)
  • Temperature Reading Accuracy: Better than ±0.5°C (±0.9°F) for -5°C to 30°C (23°F to 86°F). ±0.8°C (±1.5°F)
  • Temperature Reading Resolution: < 0.1°C/F.
  • Sensor Reaction Time: Typically less than 5 minutes (T90) in moving air (1m/s)
  • Recording Capacity: 8,001 temperature readings, 26.6 days @ 5min logging, 80 days @ 15min logging
  • Sampling Interval Configurable: From 1 minute to 18 hours
  • Logging Start Options: Push-button start or specific date & time
  • Recording Indication: Flashing ‘OK’ indicator/flashing ‘ALERT’ indicator
  • Alarms: 1 configurable upper and one configurable lower alarm
  • Download Time: Typically with full memory (8,001 readings) in less than 20 seconds from the time of insertion to availability of PDF report.
  • Environmental: IEC 60529, IP64 with USB cap fitted
  • Power Source: 3V Li-Mg Battery
  • Battery & Shelf Life: Up to 2 years before configuration, Six months operating life from the time of configuration
  • Real-Time Clock: Built-in real-time clock
  • Rated Accuracy: ±25ppm @ 25°C (equivalent to 2.5 seconds/day)
  • Rated Temperature Coefficient: -0.034, ±0.006ppm/°C (i.e typically ±0.00294 seconds/day/°C)
  • Connection: Interface USB 2.0, A-type plug
  • Size (H x W x T): 93mm x 54.5mm x 8.6mm, including protective USB cap
  • Weight: 31g
  • Case Material: Polycarbonate

USRIC-8 Single-Use Data Logger Product Brochure: Download